Friday 25 February 2011

Blood Glucose Monitoring System E02.02818

Blood Glucose Meter 

Main feature: 

Accurate 
Fast reading 
Small blood sample 
1000 Memory 
With strip ejector 

Test: Glucose 

Sample: Whole Blood 

Principle: Amperometric, Glucose Oxidase 

Measuring range: 20~600mg/DL (1.1~33.3mmol/L) 

Measuring Time: 15seconds 

Battery: One CR2032 BUTTON CELL 

Operating Temp Range: 10-40 c or 50-104 F 

Humidity: 20~80%RH 

Memory: 1000 measurement results with date and time 

Auto power off: After 2minutes without action

Nursing Trolley

unique stereamline design, patented, ABS and steel framework 

steel shelf, with raised edges and fence. 

overall dimension: 710mm×620mm×1160mm. 

package dimension: 810mm×720mm×1160mm. 

package: carton 

net wet: 30kg

Anesthesia Machine (MHJ-IIIB)

Anesthesia Machine 

A flowmeter with ORC system ensures oxygen concentration not less than 25%. 
1. With automatic N2O cut-off 
2. O2deficiency alarm 
3. SC-M3A1 anesthesia ventilator, with easy operation and low air consumption 
3. Top plate intended for all kinds of monitors 

Specifications: 

Gas supply: 0.27~0.55Mpa 
Adjustment range of flow: O2 0.1~15L/min N2O: 0.05~10L/min 
ORC system: O2 concerntration ≥25%(O2 + N2O) 
O2 deficiency alarm/ N2O cut-off: Audible alarm occurs when O2 pressure ≤0.2Mpa, N2O is cut off when O2 pressure ≤0.1Mpa 
O2 flush: 35~75L/min (O2 pressure 0.45Mpa) 
Vaporizer: 0.2~5VOL% 
Adjustment range of APL: 0.5-7kPa

Electrical Operating Table (DT12-B)

YC. DT12-B serves as a multi-purpose operationtable, suitable for thoracic abdominal surgery cerbrial surgery, ENT, gynecology and obstertriocs as well as urology surgery. 

Summary of features and properties: 

1. Integrated hydraulic. System ensures the reliablility of the table. 
2. Superior stainless steel housing for the basement and support system of the table makes cleaning and sterilization a easy matter. Ergonomic design provides the table with a clearcut. All matress are cast and made from polyster rubber. 
3. The back section of the table is movable, on which an elevator can be fit for the operation on kidney or gall-bladder. 
4. The surfaces of the table are made of plexiglass, By putting the x-ray film container between the upper and bottom deck of the table, radiographic examination can be carried out without moving the patient. 
5. All the clamps for fixing the accessories are detachable and easy to use. 
6. With the head rest and the double-sheet arm rest, which is optional accessories, the cerebral surgery and lateral surgery are convenient. 

Specification: 

Table board: 2070χ 500mm(Lχ W) 
Height of table: Minium of height 650mm, 
Adjustment range 0 to 300mm 
The lateral adjustment: -19° To +19° 
Trendlendenburg adjustment: -29° To +29° 
Back section: Up to +75° 
Head section: -90° To 45° , detachable 
Leg section: Bifurcated type, abductable up to 180 (90either side) down position up to 90 detachable. 
Foot section level with or vertical to table board, detachable. 
Elevator range of kindney bridge: >120mm 
Power Supply: 220V, 50HZ 
Electric motor: Singel phase, defferential pace, 370W 1400rpm

Mechanical Operating Table (JT-1A)

Characteritic: 

1. The new type of oil pump adopted in hydraulic pressure elevating and lowering system makes elevation very easy, the other operations are made manully. 
2. It has a compact and reasonable structure, and a superior performance and quality. 
3. The protective cove for table column is made of stainless steel. 
4. It's designed with new and fine art on the table's outline which is easy for cleaning and sterilization. 
5. All accessories can be detached with clamps. 6. By switching brake the table is convenient for transportation, moving and cleaning. 
7. A new design of handle which is flexible is used for most of adjustments. 
8. All adjustment are to be carried out at the left side of the table to make operations at most convenient. 
9. A unique features of smooth elevation. 
The mechanical operating table model JT-1A is suitable for operating on head, neck, abdomen, chest, legs and so on in general surgery as well as gynaecological and urlolgical surgery in nospitals and clinics. 

Characteritic: 

1. The new type of oil pump adopted in hydraulic pressure elevating and lowering system makes elevation very easy, the other operations are made manully. 
2. It has a compact and reasonable structure, and a superior performance and quality. 
3. The protective cove for table column is made of stainless steel. 
4. It's designed with new and fine art on the table's outline which is easy for cleaning and sterilization. 
5. All accessories can be detached with clamps. 6. By switching brake the table is convenient for transportation, moving and cleaning. 
7. A new design of handle which is flexible is used for most of adjustments. 
8. All adjustment are to be carried out at the left side of the table to make operations at most convenient. 
9. A unique features of smooth elevation. 

Technical data: 

1. Table top: Overall length 1930mm, width 480mm height adjustment 710~910mm 
2. Head section adjustment+30~90° And detachable 
3. Back section: Adjustment 0° ~75° , 
4. Leg section: Diverted range 0° ~180° , 
Adjustment 0~90° And detachable. 
5. Foot section: 
Diverted type, level with table top or vertical, and detachable 6. Trendlendenbury movement: +20° ~15° 
7. Lateral tilt: +15° ~¯ 15° 
8. Kidney bridge: Elevation up to 80mm and detachable 

Accessories: 

1. Anaesthesia screen 1 set 
2. Body supports 1 set 
3. Body straps 1 set 
4. Knee crutches 1 set 
5. Handle 
6. Single-sheet arm rest 1 set 

Optional accessories: 

1. Double-sheet arm rest 1 set 2. Versatile head rest 1 set 3. Head rest 1 set

Pulse Oximeter (Jerry-II)

± Parameters: 
Two Parameters: SPO2, Pulse Rate. 
Waveforms: 
No Waveform. 
Features: 
1. Small, light, easy for carrying and handling. 
2. Brightness LED displays, easy to read, and the brightness can be adjusted. 
3. Build-in rechargeable Ni/MH battery, longtime operating time. 
4. Audio and visual alarm, and alarm limit can be set. 
5. Automatic Power-off. 
6. Battery capacity indicator. 
H. S. Code: 90189090 
Net Weight: 0.3kg 
Gross Weight: 1.0kg 
Package Size: 210*160*70mm 
Color 
Yellow or Blue can be selected 
Standard Accessories 
One SpO2 adult finger probe 
One charger 

Specifications: 
1. General 
Monitoring Parameters: SpO2. PR. Pulse strength 
Signal sockets: SpO2 socket. Adaptor socket 
2. Display screen 
Type: Red LED 
Display area: 56mmX36mm 
Size: 120mmX63mmX32mm 
Weight: 300g(not include probes and adaptor) 
3. Features 
Audio and visual alarm: The speaker sounds the alarm and the parameter's measurement flashes on the screen. 
Prompting: Icons of battery capacity, pulse sound switch and alarm sound switch. 
Power saving: The monitor will automatic shut down when no monitoring for 3 minutes. 
4. Electrical specifications 
Working Voltage: D. C. 6.0V-D. C. 9.0V. 
AC power adaptor 
Input: AC 100 V-240V, 50/60Hz, 0.7A 
Output: 8V D. C., 800mA 
Internal battery 
Type: 2Ahr/6V Ni/MH rechargeable battery 
Run Time: 15-hour continuous operation with a new, fully charged battery (environment temperature is 2º C) 
Recharge time: 10 hours 
5. Environment 
Temperature 
Operation: 0 ~ 45 (º C) 
Transportation and storage: -20 ~ 60 (º C) 
Humidity 
Operation: 15% - 95 %( noncondensing) 
Transportation and storage: 10% - 95 % (noncondensing) 
Altitude 
Operation: 86 KPa ~106 KPa 
Transportation and storage: 50KPa~106 KPa 
6. Parameter Specifications 
SpO2 
Patient: Adult, child 
Range: 35 - 99% 
Resolution: 1 % 
Accuracy: 2 %(70% - 99%), 
PR 
Range: 0~250bpm 
Resolution: 1bpm 
Accuracy: ± 2bpm

Flame Photometer (FP-6410)

Flame Photometer 

MODEL: FP-6410 
Application Areas 
A lot of new technology and new materials are adopted. Such features as LCD display, menu-type instruction operation, curve storage, flameout protector and outside printout are enabled bu the application of top grade embedded mono-chip computer circuit. 
Performance: 
. Linear range: K: 0~30mg/I; Related coefficient: Bigger than 0.999 
. Measuring range: K: 0~10mmoI/L, Na: 0~200mmoI/L 
. Reproducibility(GV%): K: 1.5/100(5mmoI/L or -50mmoI/L), Na: 1.0/100(140mmoI/L) 
. Linear error: K: 2%; Na: 2%: Reaponse time: Not larger than 8s 
. Solution consumption: 4MI/min; Flameout detection, automatic gas cut-off function 
. RS232 interface, available to be connected with computer 
Working conditions: 
. Environmental Temperature: 10º C-35º C 
. Relative humidity≤85/100 
. The instrument should be placed horizontally, avoiding direct sunshine radiation. There is no disturbance of strong electromagnetic field or vibration. 
. Fire extinguishing device should be equipped in the application field and good aeration should be guaranteed. 
. Power supply: AC220V±22V, frequency 5OHz±1Hz, with good grounding